MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
DESIGN FUNCTIONS:
DIAGNOSTIC SETTING:
Issues Associated with the Surface Burners:
PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
TEMPERATURE PROBE NOT WORKIN | Wrong cooking mode for probe | Refer to Use/Care Guide for operation |
Probe not inserted all the way into the receptacle | Check for error codes in diagnostic mode. Insert probe into receptacle first before initiating diagnostic mode | |
Loose or defective wiring | Repair or replace wiring | |
Defective probe switch | Replace probe switch | |
Defective probe | Ohm probe, check technical data for correct ohm reading. Replace if defective |