MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
DESIGN FUNCTIONS:
DIAGNOSTIC MODE:
Issues Connected With the Surface Area Burners:
PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
POOR IGNITION AT SURFACE BURNER | Defective spark module | Replace spark module |
Burner head not properly seated on inner distribution ring | Rotate to correct position and advise owner | |
Electrode not positioned properly | Reposition electrode. Electrode should be seated down to cooktop pan. | |
Partially plugged ports in burner head | Clear/clean as necessary | |
O-rings not properly installed | Install properly or replace if defective | |
Debris on inner distribution ring | Clean/remove debris | |
Inner distribution ring has burr or crack | Replace inner distribution ring | |
Improper Gas orifice | Check orifice stamp number | |
Gas pressure | Check gas pressure with a manometer | |
Improper gas type | Check for gas type and advise owner if improper. May have to convert unit to LP/Natural gas |