MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
MODEL FEATURES:
DIAGNOSTIC MODE:
Problems Related To the Surface Heaters:
PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
INTERMITTENT SPARKING AT GRIDDLE / FT | Cracked or damaged electrode | Replace electrode |
Arc at cut or splice in electrode wire | Arc at cut or splice in electrode wire | |
Bad connection at the J1 connector on the DSI board | Perform DSI board troubleshooting procedures located at end of section 6 | |
Bad connection at the GND connector on the DSI board to unit chassis | Check GND wire connections. Ohm ground wire. Replace if defective | |
Defective DSI board | Perform DSI board troubleshooting procedure located at end of section 6 |