MODELS:
DF30 – DF36 – DF48 – DF60 DF30-3 – DF36-3 – DF48-3 – DF60-3 DF30-4 – DF36-4 – DF48-4 – DF60-4
DESIGN ATTRIBUTES:
DIAGNOSTIC SETTING:
Troubles Related To the Surface Heaters:
PROBLEM | POSSIBLE CAUSE | TEST / ACTION |
NO DISPLAY IN ECH | Temperature knob not inserted properly into selector switch | Pull temperature knob out and reinsert fully |
ECH needs to reboot | Turn circuit breaker off for 5 seconds, then turn back on | |
Circuit breaker tripped, no power | Reset circuit breaker. May have to call an electrician | |
Loose or defective wire connection(s) | Perform testing procedure located at end of section 6 | |
Defective Relay Board | Perform testing procedure located at end of section 6 | |
Defective Oven Controller | Perform testing procedure located at end of section 6 |