Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Info
Solution Diagnostics Setting enables you to identify the firmware and software program versions, examination status of “model certain” system elements as well as sensors, and alter state of components where relevant (i.e.– compressor on/off, etc.).
Enabling Service Setting: To allow Solution Mode, press and hold the “WARMER” switch while pressing the “COLDER” switch four times within 5 seconds.
After getting in Solution Setting, the first number that you will see shows the software application version number for the particular device you are servicing. For example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the very first number you will certainly see is 11. See graph listed below for matching design and software recommendation.
The 2nd number you will see suggests the software application variation launch. As an example, if you see 44 on the screen panel it suggests software version 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” button to step through Tests 0-9. The initial figure of the display screen will certainly show the examination number. The second figure indicates the current state of each element under examination and is presented as “1” being ON, CLOSED, or SHORTED and also “0” being OFF or OPEN. Tests 0 and also 1 expose an open or shorted condition found at the sensing unit inputs. Examinations 2 via 6 allow you to transform lots ON with the “WARMER” button and OFF with the “COLDER” switch. Tests 7 via 9 validate state change of the door changes and/or magnetic reed sensing unit. The part tests readily available are described in Available Component Examinations chart.
SOUND | POSSIBLE CAUSE | SOLUTION |
Buzzing | Ice maker water valve hookup buzzes when ice maker fills with water. | Normal operation |