Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Information
Solution Diagnostics Setting permits you to recognize the firmware as well as software program versions, test condition of “design particular” system elements as well as sensors, and also change state of components where suitable (i.e.– compressor on/off, and so on.).
Enabling Solution Setting: To enable Service Setting, press as well as hold the “WARMER” button while pushing the “COLDER” button 4 times within 5 seconds.
After going into Solution Mode, the first number that you will see suggests the software model number for the particular system you are servicing. For example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the very first number you will certainly see is 11. See graph listed below for matching design as well as software program recommendation.
The second number you will certainly see indicates the software application version release. For instance, if you see 44 on the screen panel it shows software variation 4.4.
Diagnostics:
While in Service Mode, press the “SET” switch to step with Tests 0-9. The very first number of the display screen will certainly reveal the test number. The second number shows the existing state of each component under examination and also is presented as “1” getting on, CLOSED, or SHORTED and “0” being OFF or OPEN. Examinations 0 as well as 1 reveal an open or shorted condition detected at the sensing unit inputs. Examinations 2 with 6 permit you to transform tons ON with the “WARMER” switch and OFF with the “COLDER” switch. Examinations 7 with 9 verify state modification of the door switches and/or magnetic reed sensing unit. The part examinations offered are explained in Offered Element Tests chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Water droplets form outside of door | Check gaskets for proper seal | Clean it |
Humidity levels are high | Hot, humid weather can increase condensation. | |
Controls require adjustment | Adjust controls |