Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Information
Service Diagnostics Setting enables you to identify the firmware as well as software program variations, test standing of “design certain” system parts and sensors, and also change state of components where suitable (i.e.– compressor on/off, and so on.).
Enabling Solution Mode: To allow Solution Mode, press and also hold the “WARMER” switch while pushing the “COLDER” switch 4 times within five secs.
After entering Solution Setting, the initial number that you will certainly see suggests the software program design number for the particular device you are servicing. For example, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the initial number you will see is 11. See graph listed below for corresponding version and also software referral.
The second number you will see shows the software program version release. For instance, if you see 44 on the display screen panel it shows software application variation 4.4.
Diagnostics:
While in Service Mode, press the “SET” switch to tip via Tests 0-9. The very first digit of the display screen will certainly reveal the examination number. The second figure suggests the present state of each element under test and also is displayed as “1” getting on, CLOSED, or SHORTED and “0” being OFF or OPEN. Tests 0 as well as 1 reveal an open or shorted condition spotted at the sensing unit inputs. Tests 2 via 6 permit you to turn lots ON with the “WARMER” switch and OFF with the “COLDER” switch. Examinations 7 via 9 verify state adjustment of the door changes and/or magnetic reed sensor. The element examinations readily available are described in Offered Element Tests chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
MeatSavor drawer temperature is too warm | Control settings are too low. | See p 5 to properly adjust controls. |