THERMADOR Range/Stove/Oven Fault Codes starting with an E. If a mistake apears in the cook mode home window.
Your stove is equipped with a very dependable as well as exact electronic control. On the unusual event that something occurs that causes a breakdown, an error message will show up in the stove selector window. Some errors (E1, E9, E11, E12, and E13) should be gotten rid of by turning off the stove at the circuit breaker and afterwards transforming it back on. When an error continues to be shown continuously in the off placement, after attempting to clear the error, a service phone call is required. Have the mistake code readily available when you require solution. This will help service figure out the problem.
Error Code | NOTES | CHECK/REPAIR |
E1 | C,E | Control board problem |
E2 | K,G | Cook or clean mode runaway |
E3 | A,H | Open oven temperature sensor (over 5000 ohms) |
E4 | A,H | Shorted oven temperature sensor (under 500 ohms) |
E5 | K,D | Control board too cold or too hot, or defective board. |
E6 | C,J | Control board problem |
E7 | A,I | Illegal temp display turn off and retry |
E8 | A,D | Control board problem |
E9 | A,E | Latch switch problems |
E10 | B,D | Control board problem |
E11 | A,F | CT oven; latch switch problem |
E12 | A,E | CT oven; latch switch problem |
E13 | A,C | CT ovens; latch froze or no power to latch motor CMT ovens; control board not converted |
E14 | A,E | Latch switch problems |
E15 | B,D | Control board problem |
ERROR CODE | NOTE | CHECK REPAIR |
F0 | Internal logic failure; cancel key supervision. Sounds alarm and resets to non-cook mode | Replace the electronic range control (also called clock or ERC) |
F1 | Internal logic failure (monitoring function). Sounds alarm and inhibits cook modes | Replace the electronic range control (also called clock or ERC) |
F2 | Temperature runaway detected (Bake/Broil: 600 – 700 F; Clean: 930 – 1000 degrees F). Sounds alarm and resets to non-cook mode. Check relay board for stuck contacts. Check oven temperature sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check sensor wiring connectors for a loose or high resistance connection. Check electronic range control (also called clock or ERC) functions | Replace relay board if necessary. Replace oven temperature sensor if other components check normal. If failure repeats, replace electronic range control (also called clock or ERC) |
F3 | Open circuit detected; oven temperature sensor. Check sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check wires and connections between electronic range control (also called clock or ERC) and oven temperature sensor | Replace sensor if other components check normal. Replace electronic range control (also called clock or ERC) if fail code reoccurs |
F4 | Short circuit detected; oven temperature sensor. Check sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check wires between electronic range control (also called clock or ERC) and sensor. | Replace sensor if other components check normal. Replace electronic range control (also called clock or ERC) if fail code reoccurs |
F7 | Function key shorted for over 16 seconds. Check for something pressing a key or preventing normal release of the key | Replace electronic range control (also called clock or ERC) if other components check normal |
F8 | Internal logic failure; calibration. Alarm sounds and resets to non-cook mode. Check oven temperature sensor for normal room temperature resistance (1085-1097 ohms at 75 F). Check wires and connections between electronic range control (also called clock or ERC) and oven temperature sensor | Replace electronic range control (also called clock or ERC) and oven temperature sensor if other components check normal |
F9 | Internal logic ailure; door latch supervision. Alarm sounds and resets to non-cook mode. If door is locked due to clean temperatures, disconnect power until door can be unlocked | Replace the electronic range control (also called clock or ERC) |
Fd | Bake & Broil relay drives active simultaneously. Check relay board for damage: trace E6 to K2 & K3, and burned contacts K3 & K3 | Replace electronic range control (also called clock or ERC). Replace relay board if necessary |
Blank Display | No power to lectronic range control (also called clock or ERC). Check oven light and cooktop dial lights (powered by L2 & L1, respectively). Check relay board transformer primary, E1 to E2 (140 ohms typical). If the transformer internal fuse is still OK, check output voltages, pins 9 – 8 (3.2 v.a.c.) and 7 – 6 (21 v.a.c.). Check clock functions after replacing relay board | If relay board transformer open (E1 to E2), replace relay board. If still no clock functions replace electronic range control (also called clock or ERC) |