THERMADOR Error Code Blank Display
Professional Ranges Models: PDR30/36/48…PRG30/36/48
ERROR CODE | DESCRIPTION | RESOLUTION |
CODE Blank Display | No power to electronic range control (also called clock or ERC). Check oven light and cooktop dial lights (powered by L2 & L1, respectively). Check relay board transformer primary, E1 to E2 (140 ohms typical). If the transformer internal fuse is still OK, check output voltages, pins 9 – 8 (3.2 V.A.C.) and 7 – 6 (21 V.A.C.). Check clock functions after replacing relay board | If relay board transformer open (E1 to E2), replace relay board. If still no clock functions repair electronic range control (also called clock or ERC) |
The control continually keeps an eye on system specifications for control and also stove failings and reports a fault code when a system issue is spotted. The control utilizes the stoves blue “on light” and oven “home heating light” to report a discovered mistake code. The control will continue to blink the lights in the ideal sequence as long as the fault exists.
Discovery of a mistake does not prevent the capability of the control to continue to function if the mistake is not essential for the desired procedure. For instance: If the range door latch is defective, the range will certainly remain to prepare since the mistake would only avoid the variety from self-cleaning.
HOW TO ANALYZE CODES
When a fault takes place, the control will certainly blink heaven stove “on light” and the Blue “home heating light” sequentially to indicate the fault. The fault codes have two numbers, these numbers are analyzed by the number of times the lights blink. The stove “on light” will certainly flash indicating the very first number, and the “home heating light” will blink showing the 2nd number.
EXAMPLE:
Error E9 is … No Cooling Followers. The code is 43. The stove “on light” will blink 4 times, after that the “heating light” will certainly flash three times, after that pause. The series will then duplicate as long as the fault exists.
MISTAKE CODES FOR OVENS WITH DREEFS CONTROL
The adhering to chart reveals the error codes that can be displayed in the Oven/Selector window during specific oven breakdowns. Several of the error messages can be removed by executing the adhering to steps:
ERROR CODE | NOTE | CHECK REPAIR |
F0 | Internal logic failure; cancel key supervision. Sounds alarm and resets to non-cook mode | Replace the electronic range control (also called clock or ERC) |
F1 | Internal logic failure (monitoring function). Sounds alarm and inhibits cook modes | Replace the electronic range control (also called clock or ERC) |
F2 | Temperature runaway detected (Bake/Broil: 600 – 700 F; Clean: 930 – 1000 degrees F). Sounds alarm and resets to non-cook mode. Check relay board for stuck contacts. Check oven temperature sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check sensor wiring connectors for a loose or high resistance connection. Check electronic range control (also called clock or ERC) functions | Replace relay board if necessary. Replace oven temperature sensor if other components check normal. If failure repeats, replace electronic range control (also called clock or ERC) |
F3 | Open circuit detected; oven temperature sensor. Check sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check wires and connections between electronic range control (also called clock or ERC) and oven temperature sensor | Replace sensor if other components check normal. Replace electronic range control (also called clock or ERC) if fail code reoccurs |
F4 | Short circuit detected; oven temperature sensor. Check sensor for normal room temperature resistance (1085-1097 ohms at 75 degrees F). Check wires between electronic range control (also called clock or ERC) and sensor. | Replace sensor if other components check normal. Replace electronic range control (also called clock or ERC) if fail code reoccurs |
F7 | Function key shorted for over 16 seconds. Check for something pressing a key or preventing normal release of the key | Replace electronic range control (also called clock or ERC) if other components check normal |
F8 | Internal logic failure; calibration. Alarm sounds and resets to non-cook mode. Check oven temperature sensor for normal room temperature resistance (1085-1097 ohms at 75 F). Check wires and connections between electronic range control (also called clock or ERC) and oven temperature sensor | Replace electronic range control (also called clock or ERC) and oven temperature sensor if other components check normal |
F9 | Internal logic ailure; door latch supervision. Alarm sounds and resets to non-cook mode. If door is locked due to clean temperatures, disconnect power until door can be unlocked | Replace the electronic range control (also called clock or ERC) |
Fd | Bake & Broil relay drives active simultaneously. Check relay board for damage: trace E6 to K2 & K3, and burned contacts K3 & K3 | Replace electronic range control (also called clock or ERC). Replace relay board if necessary |
Blank Display | No power to lectronic range control (also called clock or ERC). Check oven light and cooktop dial lights (powered by L2 & L1, respectively). Check relay board transformer primary, E1 to E2 (140 ohms typical). If the transformer internal fuse is still OK, check output voltages, pins 9 – 8 (3.2 v.a.c.) and 7 – 6 (21 v.a.c.). Check clock functions after replacing relay board | If relay board transformer open (E1 to E2), replace relay board. If still no clock functions replace electronic range control (also called clock or ERC) |
ERROR CODE | NOTES |
A | Turns heat off on the failed oven only; microwave not affected. |
B | Turns all heat off; microwave not affected. |
C | Disables the CLEAN mode in both ovens; allows COOK and microwave. |
D | Error will remain in the display until oven is repaired and powered back up. No error tones. |
E | Turning the oven off stops the error and flashing display. Can tweak away the error code. Error is redisplayed only if the selector is turned to CLEAN. |
F | Tweaking clears to “—“ for retry. |
G | Clears when the oven temperature is less then the runaway temperature with the selector switch off. |
H | Can be cancelled by tweaking if a good sensor is detected. |
I | Cleared with a mode change. |
J | Can be tweaked away for immediate retry. User must unlatch and delete the “—“ to try to relatch the door. |
K | Turns heat and microwave off. |
L | If two switches show a locked door, then E13 and LOCK are permanent in the display (in all modes). If the two switches show an open door, tweak away the E13 error message. |